Permanent-magnet vs electrically-excited synchronous motors

PMSM and EESM look alike and run just as accurately, but inside they differ greatly. This page contrasts excitation, efficiency, cost and where each fits so selection avoids mistakes.

1. How it works

A permanent-magnet synchronous motor uses NdFeB magnets on the rotor, needs no excitation current, slip rings or brushes, and is simple and reliable. An electrically-excited synchronous machine feeds DC to the rotor through slip rings or a rotating rectifier, letting field strength vary. PMSM has no excitation loss and no maintenance; EESM can flex power factor and voltage but carries brush wear and excitation loss.

2. Practice and pitfalls

PMSM efficiency is higher, especially at part load, with greater power density and smaller size, making it the choice for servos and new energy. EESM loses a little efficiency but can over-excite to support the grid with reactive power, and at very large high-speed ratings the magnet cost and demagnetisation risk make EESM cheaper. Choose PMSM for compact efficient drives like servos and EVs; choose EESM for large adjustable-power-factor or harsh high-speed duties like generators and mills. Note PMSM cannot adjust excitation and loses magnetism under high temperature or reverse field, while EESM with lost excitation simply falls out of step.

3. PMSM versus electrically excited synchronous machines

ItemPMSMEESMVerdict
ExcitationPermanent magnetsDC fieldDifferent
EfficiencyHighSlightly lowerPMSM wins
MaintenanceNoneBrush wearPMSM wins
PF controlNot possibleYesEESM wins
Where usedServo, new energyLarge generationPer duty

4. Notes

A PMSM wastes nothing on field current, needs no brushes and packs the highest efficiency and power density, making it the default for servos and new-energy drives. An EESM can regulate power factor and survives very large ratings and speeds, but its brushes need upkeep. Pick PMSM for compact efficiency, EESM for large capacity with PF control; note PMSM fears demagnetisation at temperature and an EESM drops out of step the moment the field fails.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machines: GB/T 755 / IEC 60034-1; product standards for permanent-magnet machines apply. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Expecting a PMSM to regulate power factor like a wound field machine: it simply cannot
② Running a PMSM hot without demagnetisation protection lets the magnets lose flux
③ Assuming an EESM behaves like a PMSM after losing excitation: no field means it falls out of step

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.