Deriving the voltage-divider and current-divider rules

Series: same I everywhere, so U1=U·R1/(R1+R2); drops are proportional to resistance.

1. How it works

Parallel: same U, so I1/I2=R2/R1; the numerator is the opposite resistor - the classic mix-up.

2. Practice and pitfalls

General case: current splits by conductance, Ik=I·Gk/ΣG; always check ΣU=U and ΣI=I.

3. Formula summary

CircuitFormulaRatioCheck
Divider (2)U1=U·R1/(R1+R2)U1/U2=R1/R2U1+U2=U
Divider (n)U·Rk/ΣRDrop ∝ RΣUk=U
Shunt (2)I1=I·R2/(R1+R2)I1/I2=R2/R1I1+I2=I
Shunt (n)I·Gk/ΣGI ∝ GΣIk=I
Two equalI/2 each1:1Sum=I
Pot unloadedU·kPositionk=1 → U

4. Notes

Apply the points above to Deriving the voltage; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 3102.5, IEC 60115 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Putting the own branch in the shunt numerator
② Using the 2-branch formula on n branches
③ Skipping the sum checks

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.