Series: same I everywhere, so U1=U·R1/(R1+R2); drops are proportional to resistance.
Parallel: same U, so I1/I2=R2/R1; the numerator is the opposite resistor - the classic mix-up.
General case: current splits by conductance, Ik=I·Gk/ΣG; always check ΣU=U and ΣI=I.
| Circuit | Formula | Ratio | Check |
|---|---|---|---|
| Divider (2) | U1=U·R1/(R1+R2) | U1/U2=R1/R2 | U1+U2=U |
| Divider (n) | U·Rk/ΣR | Drop ∝ R | ΣUk=U |
| Shunt (2) | I1=I·R2/(R1+R2) | I1/I2=R2/R1 | I1+I2=I |
| Shunt (n) | I·Gk/ΣG | I ∝ G | ΣIk=I |
| Two equal | I/2 each | 1:1 | Sum=I |
| Pot unloaded | U·k | Position | k=1 → U |
Apply the points above to Deriving the voltage; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 3102.5, IEC 60115 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.