After the bridge the capacitor charges near each peak and discharges into the load between peaks, like a water tank smoothing pulsed inflow into steady output - the level ripple is the voltage ripple.
Sizing: C ≥ I·t/ΔU with t = half cycle (10ms at 50Hz bridge). Example: 1A load, 1V ripple → 10000µF, fit 1.2~1.5×. Cross-check the rule of thumb 2000~3000µF per ampere for small supplies; take the larger.
Fit an NTC or series resistor against the multi-ampere inrush, rate the capacitor 1.3~1.5× the peak bus voltage, add a small HF capacitor at the load end to cover the electrolytic's ESR, and verify ripple with the scope's AC coupling.
| Load current | Allowed ripple ΔU | Calculated C | Practical pick |
|---|---|---|---|
| 0.1A | 0.5V | 2000µF | 2200~3300µF |
| 0.5A | 0.5V | 10000µF | 10000~15000µF |
| 1A | 1V | 10000µF | 12000~15000µF |
| 2A | 1V | 20000µF | 22000µF bank |
| 5A | 2V | 25000µF | 4×6800µF parallel |
| 10A | 2V | 50000µF | Bank + NTC inrush limiter |
The formula gives the floor; fit 1.2~1.5×. For tight ripple specs enlarge the bank rather than leaning on the regulator - its headroom is finite and a rough bus destabilises it first.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Sizing here is engineering practice; capacitor application per GB/T 2693 series, DC-link capacitors per IEC 61071. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.