Reading the torque-frequency curve of a stepper

A stepper loses torque fast with speed, and this curve decides how fast you can run. This page explains how to read the torque-speed curve, start and max frequency, and how to use it for selection.

1. How it works

The horizontal axis is step frequency, the vertical is available torque. Torque is highest at low frequency, the holding or start torque, then falls monotonically because winding inductance limits current build-up and back-EMF grows. Where the curve drops to the load torque the motor can no longer hold and loses steps above that. That fall is the open-loop stepper weakness.

2. Practice and pitfalls

Start frequency is the highest pulse rate the motor can start without losing steps, hundreds to a few thousand pps, lower with heavier load. Maximum frequency is the running limit once already spinning, higher than start because inertia helps. Selection must satisfy both with 20 to 30 percent margin: check start with f_st and running with f_max. Draw the load torque line; right of the intersection is unusable. For high speed with torque, pick a flatter low-inductance motor, reduce microstepping, or raise drive voltage. The curve is the core open-loop selection tool.

3. Reading the torque-frequency curve of a stepper

ParameterMeaningTypicalUse
Holding torqueStatic maximumNameplate valueBaseline
Start frequencyMax without rampHundreds~1kCheck starting
Max frequencyRunning limitHigherCheck running
Fall-off regionTorque collapsesHigh freqAvoid
MarginReserve20%~30%For stability

4. Notes

The torque-frequency curve peaks at low speed and falls monotonically as inductive current lag and back-EMF bite; where it crosses the load demand, the motor loses steps. The start frequency is the maximum for a standing start without ramp (lower with heavier load), and the max frequency applies only once already spinning. Check both against the load with 20%~30% reserve; if torque falls short at target speed, slow down or pick a bigger, lower-inductance motor.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Steppers per applicable standards; electrical safety: GB/T 5226.1 / IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Using the maximum running frequency as the start frequency stalls the motor at the first move
② Sizing by feel without the curve runs out of torque exactly at high speed
③ Letting the load line cross the curve loses steps in the middle of the move

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.