The spark grade under the brushes is the health report of commutation: grade 1 is normal, grade 2 is a warning, grade 3 means stop now. This page gives the grading criteria, field identification tricks and graded remedies.
The conventional scale runs through five grades. Grade 1 shows no sparking and no blackening. Grade 1.25 shows faint point sparks at part of the brush edge with a clean commutator. Grade 1.5 adds light sparks over most of the edge and black marks that gasoline removes. Grade 2 means strong sparks along the whole edge, permanent black marks and burned brush faces: tolerable for brief overloads, not for continuous running. Grade 3 is explosive sparking with tongues of flame, permitted only at the instant of opening the circuit, demanding an immediate stop in operation.
Field identification relies on eyes and cloth: watch the trailing brush edge, and judge history from the marks, since marks around the whole commutator point at brushes and springs while marks on a few bars point at interbar voltage or windings. An IR thermometer on the holders, normal below 90C, adds objectivity, and wiping with a gasoline-dampened cloth settles the boundary between grade 1.5 and 2. Remedies follow the cause: commutating pole compensation for load-dependent sparking, brush section or count for excessive current density, induction method for neutral shift, gentle polishing for surface roughness.
| Grade | Appearance | Permitted state | Action |
|---|---|---|---|
| grade 1 | no sparks or rare tiny points | continuous operation allowed | routine maintenance |
| grade 1.25 | faint points on part of edge | continuous operation allowed | routine maintenance |
| grade 1.5 | light sparks on most of edge | continuous operation allowed | tighter inspection interval |
| grade 2 | strong sparks, removable black marks gone | short time only | stop and inspect commutation |
| grade 3 | explosive sparks with flame | only when opening circuit | immediate shutdown |
| flashover precursor | arcing joining into a fire ring | not permitted | de-energize, check interbar insulation |
Compare grades only under the same load: a motor at grade 1 unloaded and grade 2 loaded needs compensation checked, while grade 2 at no load goes straight to brushes and neutral. Trend the records rather than trusting one reading.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Commutation spark assessment per GB/T 1311 (DC machine test methods); duty and ratings per GB/T 755 (IEC 60034-1). Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.