Back electromotive force mirrors the speed of a DC motor: one equation links voltage, flux and rotation. Starting from the voltage balance, the relationship can be derived and then used to estimate speed in the field without dismantling the coupling.
A rotating armature conductor cutting flux generates an EMF opposing the applied voltage. The armature circuit balances as U = E + IaRa plus roughly 2V of brush drop. With no load the current is small and E nearly equals U; as load grows the resistive drop eats into E and speed falls, which is the electromagnetic essence of load-dependent speed. Deriving the constant: the average conductor EMF combines with the flux per pole relation and the number of effective conductors to give E = Ce times flux times speed, where Ce depends only on poles, conductors and parallel paths, and the torque constant is simply 9.55 times Ce.
Worked example on a shunt motor: supply 220V, armature resistance 0.5 ohm, rated current 40A gives rated E of about 198V; at 3A no-load current E is about 215.5V, so the idle speed runs roughly 8.8 percent above rated. In the field, measure Ra with a double bridge, compute E from the running current, and scale the nameplate speed accordingly, accurate to about 3 percent for trend analysis. The same logic explains starting: with n = 0 there is no back-EMF, so the current is limited only by Ra and reaches 5 to 7 times rated unless a starter intervenes.
| Condition | Armature current | Back-EMF E | Speed ratio |
|---|---|---|---|
| nameplate rated | 40A | about 198V | 1.000 (rated speed) |
| no load | 3A | about 215.5V | about 1.09 (9% faster) |
| half load | 20A | about 208V | about 1.05 (5% faster) |
| overload 1.2x | 48A | about 192V | about 0.97 (3% slower) |
| field weakened 5% | 40A | flux drops, speed rises | about 1.05 at same current |
| starting instant | up to 5~7x rated | E about 0 (n = 0) | zero speed, maximum current |
Use a bridge, never a multimeter, for milli-ohm armature resistance: contact resistance swamps the winding and ruins the calculation. Log no-load and loaded E and speed after overhaul for next-time comparison.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1311 (DC machine test methods) and GB/T 755 for testing and acceptance requirements. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.