An Ex label is not decoration; every letter encodes which zone, gas group and temperature class the device survives. This page decodes the marking system and matches equipment types to area classifications.
Hazardous gas areas classify as Zone 0 where explosive atmosphere is present continuously, Zone 1 likely in normal operation, Zone 2 only in abnormal cases; dust areas mirror as 20, 21, 22. Equipment types map onto these: intrinsic safety Ex ia is the only general choice for Zone 0 because it limits energy below ignition levels, while flameproof Ex d, increased safety Ex e and Ex ib suit Zone 1, and Zone 2 additionally accepts normal purpose or Ex n equipment.
The gas group matters next: IIA covers propane like gases, IIB ethylene like, IIC hydrogen and acetylene, and an IIC marked device may serve any group while the reverse is false. Temperature classes T1 to T6 set the maximum surface temperature from 450 down to 85 degrees, matched against the auto ignition temperature of the gas; a T3 motor never goes near carbon disulfide. On site, the discipline is to read the certificate before installing anything in the zone, keep the special fasteners and gaskets that make an enclosure flameproof intact, and never drill or stuff unused entries that destroy the rating.
| Area zone | Permitted types | Group requirement |
|---|---|---|
| Zone 0 gas | Ex ia intrinsic safety | Matched to the gas |
| Zone 1 gas | Ex d, Ex e, Ex ib | IIB or IIC as needed |
| Zone 2 gas | Ex n and above | IIB typical |
| Hydrogen areas | IIC marked equipment | Strictest group |
| Dust Zone 22 | Dust protection type | Temperature class to suit |
Classify the zone first, then pick the Ex type and gas group with temperature class. Flameproof enclosures for Zone 1, intrinsic safety ia for Zone 0, and every installation keeps the certified integrity intact.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Explosive atmospheres follow the GB 3836 series, aligned with IEC 60079, and dust explosion protection GB 12476, with reference to IEC 60079 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.