Flip-flops come in level-triggered and edge-triggered flavors and mixing them up wrecks the timing. This page contrasts when each one samples and where run-through and glitches come from.
A level-triggered device, a gated RS or a transparent latch, listens to its inputs during the whole active clock level. It is transparent and fast, but any input change inside the window propagates to the output, so the state can run through several times and input glitches pass straight in. It suits bus latching, where the capture moment is a window rather than an instant.
An edge-triggered device samples D only at the rising or falling edge of the clock and freezes the output otherwise, so the output updates once per cycle, run-through is impossible and glitches are rejected. D flip-flops and edge JK parts work this way. The price is the setup and hold window around the edge and a maximum clock frequency.
Reading the symbol: a small triangle on the clock input marks edge triggering, no triangle means level, and a bubble outside the triangle marks the falling edge. Check the part number too: the 74LS373 is a level latch while the 74LS374 is edge triggered, one digit apart with opposite behavior, so always read this mark before substituting a chip on site.
| Item | Level triggered | Edge triggered |
|---|---|---|
| Sampling moment | Whole CP active level | One instant at the edge |
| Run-through risk | Yes | None |
| Glitch sensitivity | Sensitive | Rejects glitches |
| Typical part | 74LS373 | 74LS374 |
| Symbol mark | No triangle | Clock triangle |
| Best use | Bus latching | Registers and counters |
Use a level part (373) for bus latching and an edge part (374) for shifting and counting. When substituting chips read the triangle mark; one digit apart means opposite behavior.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Triggering modes per GB/T 4728 and IEC 60748 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.