You only have single-phase power but need a three-phase motor to run; it is possible but comes with a price. This page states which motors can be converted, how to wire the capacitor, and the power penalty.
Only small low-pole three-phase motors, typically 3 kW and below, suit conversion. The method uses a capacitor to split phase and create a rotating field, but the winding is asymmetric so efficiency and output drop sharply to about 50 to 70 percent of nameplate, and rotation is single direction. Wound-rotor, large and multi-speed motors should not be converted; buy a single-phase motor instead.
The common wiring feeds 220 V to two phases and inserts a run capacitor in the third phase, with C about 0.06 to 0.1 times power in watts over voltage squared in microfarads. A permanently connected capacitor gives capacitor-run operation good for light fan loads; reversing swaps the capacitor connection. Use an AC capacitor rated 450 V or more, never an electrolytic. Start torque falls to 30 to 50 percent, so heavy starting is hard and the motor runs hotter. For continuous or heavy duty, fit a single-phase VFD rather than convert.
| Item | Original three-phase | After conversion | Remark |
|---|---|---|---|
| Power | 100% | 50%~70% | Discounted |
| Starting torque | 100% | 30%~50% | Weak |
| Direction | Swappable | Swap capacitor ends | Reversible |
| Capacitor voltage | None | >=450 V | AC type |
| Suitability | Small power | Emergency only | Not permanent |
Converting a three-phase motor to single phase is an emergency trick for small motors only: output drops to five or seven tenths, starting torque is weak, and long loaded runs overheat it. Use AC capacitors rated 450 V or more, size them by rough formula then trim by test. Buying a single-phase motor or a single-phase VFD is always better; identify winding ends before wiring.