To stop an induction motor fast you can use dynamic braking or plugging, one smooth and one violent. This page explains both principles, wiring, braking torque and where each fits so you do not burn the motor by using the wrong one.
Dynamic braking, also called DC injection, feeds a direct current, typically 0.5 to 1 times rated, into the stator the instant AC is removed, creating a stationary field. The spinning rotor cuts this field, induces current and produces braking torque that dissipates kinetic energy as rotor heat. Torque grows with DC current and speed, usually set at 50 to 100 percent rated. It is smooth, never reverses and allows accurate stop, but needs a rectifier, loses torque at low speed and must be cut after stop to avoid locked rotor heating.
Plugging reverses the field by swapping any two supply phases, turning torque into the braking direction and yanking the rotor to rest. Brake torque is large and stop fast, but the current spikes 5 to 10 times rated, so a wound rotor must insert resistance or a plug relay must cut power near zero speed, otherwise the machine reverses and runs backward. It is harsh, hot in the windings and limited in repeat count, suiting large inertia stops that are infrequent. Choose dynamic braking for smooth accurate stops like machine spindles, plugging for fast large inertia occasional stops. Wire dynamic braking with a rectifier and contactor, feed DC on two phases, time 1 to 5 seconds; always fit a speed relay to plugging to cut near 100 r/min, and add a mechanical brake for frequent duty.
| Item | Dynamic braking | Plugging |
|---|---|---|
| principle | DC makes still field | swap two phases reverse field |
| torque | smooth adjustable | large violent |
| surge current | small | 5 to 10x rated |
| reverse | none | may reverse run |
| use | accurate stop | fast large inertia |
| heating | rotor dissipates | winding heats heavy |
Pick dynamic braking for smooth accurate stops and plugging for fast infrequent large inertia, but plug only with a speed relay cutting near zero and current limiting, since plugging current hits 5 to 10 times and heats the winding. Time DC injection 1 to 5 seconds and never leave it on after stop. Use a mechanical brake for frequent duty.