MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › How a three phase induction motor makes a rotating magnetic field and starts to spin
HomeModels
Table of contents

On this page

Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

How a three phase induction motor makes a rotating magnetic field and starts to spin

A three phase induction motor spins because its stator creates a magnetic field that rotates on its own, and the rotor is dragged along by induction. This page explains where the rotating field comes from and why the rotor must lag behind it.

1. How it works

The stator carries three windings spaced 120 electrical degrees apart. Feeding them three currents also 120 degrees apart produces a resultant magnetomotive force of constant amplitude that revolves at synchronous speed. At every instant the field axis follows the instantaneous currents, and as the 50 Hz currents peak in turn the axis sweeps one full turn per cycle. With two poles the field turns once per electrical cycle, so synchronous speed is 60 f over p, giving 3000 r/min for a two pole machine on 50 Hz.

2. Practice and pitfalls

The rotating field cuts the rotor bars and induces current in the closed rotor circuit. The current carrying bars feel force in the field and produce torque that pulls the rotor toward the field. Yet the rotor speed n must stay below synchronous speed n0, because at equality there is no relative cutting, no induced current and no torque. That slip is the whole point: rated slip runs about 2 to 5 percent. Swap any two supply phases to reverse the field direction, which reverses rotation without harming the windings.

3. Poles and synchronous speed

Poles pSynchronous speed r/minTypical use
2 pole3000pumps, high speed fans
4 pole1500machine tools, compressors
6 pole1000hoists, winches
8 pole750low speed high torque
10 pole600mills, mixers

4. Notes

The rotating field is the root of every induction motor behaviour. Match the nameplate poles and supply frequency to set synchronous speed, and remember the rotor must lag to deliver torque. When replacing a motor or changing frequency, check poles against the drive rating; a reversed phase order only needs two leads swapped.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rated performance per GB/T 755 (IEC 60034-1); rotation direction marking per GB/T 1971. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① set a 4 pole motor with 2 pole drive parameters: pole mismatch spikes current and overheats
② expect torque at zero slip: equal speeds kill induced current and stall the load
③ replace without reading pole count: speed off by a factor of two or lockout

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL