Multiple VFDs: output paralleling, common DC bus and mains sharing

Direct output paralleling of ordinary VFDs is forbidden; true output sharing needs master-slave torque control.

1. How it works

Common DC bus is the everyday 'parallel': mind polarity, braking energy (worst-case simultaneous regeneration) and section isolation.

2. Practice and pitfalls

Mains-side sharing is a harmonics and cable calculation per GB/T 14549.

3. Topology table

SchemeFeasibilityKey measuresApplication
Output parallel (plain)Forbidden——
Output parallel (M/S)FeasibleTorque follow+syncTwin motors
Common DC busRoutinePolarity, brakingMulti-axis lines
Mains sharingRoutineHarmonicsWorkshop feed
Shared brake unitRoutineEnergy budgetHoist groups
Bus sectioningRoutineSection switchHigh availability

4. Notes

Apply the points above to Multiple VFDs; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 14549 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Paralleling VFD outputs without master-slave
② Reversed DC bus polarity
③ Sizing braking for one drive only

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.