Holding torque versus pull-in torque of steppers

Holding torque and pull-in torque are often mixed up but differ a lot. This page defines each, their test conditions, and which to use for selection.

1. How it works

Holding torque is the maximum static torque the energised but stationary motor can resist without continuous rotation; it is the headline spec, say 0.4 or 1.2 N·m for a 1.8-degree motor, and the basis for sizing with a safety factor. Hybrid types keep some holding when off from the magnet, less than powered holding. Pull-in torque is the maximum torque the motor can start and synchronise at a given pulse frequency without losing steps; it is dynamic and falls with frequency along the start region of the torque-speed curve, much smaller than holding because it must overcome inertia and acceleration.

2. Practice and pitfalls

Sizing on holding torque alone overestimates real load capacity; for motion, especially start and acceleration, use pull-in torque or the curve at the target frequency, keeping load at 50 to 70 percent of pull-in for margin. Driver current, microstep and voltage shift the real values, so verify on site.

3. Holding torque versus pull-in torque of steppers

MetricNatureConditionFor sizing
Holding torqueStaticEnergised, blockedLocking baseline
Pull-in torqueDynamicAt a given frequencyStart and run
Detent torqueMagnet dragPower off, smallBrake assist
MagnitudeHolding largerPull-in smallerNever confuse
Margin50%~70%Of pull-inAnti-slip reserve

4. Notes

Holding torque is the maximum static locking torque with the motor energised and blocked, the headline figure of the datasheet; pull-in torque is the largest torque at which the motor can start without losing steps at a given frequency, falling with speed and far below holding. Size statics by holding, motion by pull-in at the working frequency, and load the motor to 50%~70% of pull-in for reserve. Never judge duty capacity from holding torque alone.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Steppers per applicable standards; electrical safety: GB/T 5226.1 / IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Sizing by holding torque alone underestimates the duty and the motor loses steps in motion
② Counting on a power-off PM motor to hold: without a brake the load drifts
③ Ignoring pull-in at speed means the first high-speed start drops steps immediately

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.