The parallel branch count a in a motor winding is an often ignored parameter: same winding with different a changes current turns per coil and lead out style. This page explains pole phase groups and the constraint of a.
A pole phase group is the coil group of one phase under one pole. Each phase winding may be series parallel or mixed by several pole phase groups and the parallel branch count a is how many paths the phase current splits into. Larger a means fewer turns per path and thicker wire.
Parallel branch count a must be a divisor of the pole count 2p: a 4 pole motor may take a equal 1 2 or 4; a 6 pole may take 1 2 3 or 6. It cannot be arbitrary. On rewind if a is missed or a branch is reversed the three phase resistance becomes unbalanced and output torque drops; a reversed branch even cancels torque. Always record a from the original.
| Poles | Pole pairs | a options | Constraint |
|---|---|---|---|
| 2 pole | 1 | 1 2 | a divides 2p |
| 4 pole | 2 | 1 2 4 | a divides 2p |
| 6 pole | 3 | 1 2 3 6 | a divides 2p |
| 8 pole | 4 | 1 2 4 8 | a divides 2p |
| Miss a | unbalanced | low torque | record |
| Reverse | one branch | cancel | check |
Parallel branch count a is the number of parallel paths per phase and must divide the pole count 2p with each branch identical. Missing a on rewind unbalances three phase resistance; a reversed branch cancels torque. Always record a and lead out from the original winding.