Motor winding parallel branches and pole phase groups

The parallel branch count a in a motor winding is an often ignored parameter: same winding with different a changes current turns per coil and lead out style. This page explains pole phase groups and the constraint of a.

1. How it works

A pole phase group is the coil group of one phase under one pole. Each phase winding may be series parallel or mixed by several pole phase groups and the parallel branch count a is how many paths the phase current splits into. Larger a means fewer turns per path and thicker wire.

2. Practice and pitfalls

Parallel branch count a must be a divisor of the pole count 2p: a 4 pole motor may take a equal 1 2 or 4; a 6 pole may take 1 2 3 or 6. It cannot be arbitrary. On rewind if a is missed or a branch is reversed the three phase resistance becomes unbalanced and output torque drops; a reversed branch even cancels torque. Always record a from the original.

3. Parallel branch and pole constraint table

PolesPole pairsa optionsConstraint
2 pole11 2a divides 2p
4 pole21 2 4a divides 2p
6 pole31 2 3 6a divides 2p
8 pole41 2 4 8a divides 2p
Miss aunbalancedlow torquerecord
Reverseone branchcancelcheck

4. Notes

Parallel branch count a is the number of parallel paths per phase and must divide the pole count 2p with each branch identical. Missing a on rewind unbalances three phase resistance; a reversed branch cancels torque. Always record a and lead out from the original winding.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machine winding see IEC 60034-1 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Rewind missing parallel count a unbalances resistance and output
② One branch reversed cancels torque sharply
③ Choosing a not dividing 2p impossible to connect

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.