Three levels: continuity check for shorts, capacitance mode for value, charge/discharge observation for leakage.
De-energize, discharge and lift one leg; compare with the rated value (-20% on electrolytics means dried out).
In switch-mode supplies check ESR - normal capacitance with doubled ESR is already a failure.
| Method | For | Criterion | Limit |
|---|---|---|---|
| Continuity | Shorts | Beeper = dead | No value |
| Capacitance mode | Value | ±20% vs rating | In-circuit errors |
| Analog charge test | Leakage | Return swing | Experience needed |
| Hipot test | Maintenance | Leakage limit | Special仪器 |
| ESR meter | SMPS repair | ESR limit | Lift one leg |
| Visual | Bulging | Replace at once | Auxiliary |
Apply the points above to Testing capacitors with a multimeter; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per IEC 60384, GB/T 2693 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.