RC charging time constant in power-up delay design

UC=U(1−e−t/τ): 63.2% at 1τ, 95% at 3τ; delay time t=−τ·ln(1−threshold).

1. How it works

Design: pick the threshold ratio (usually 1τ), set τ=t, check leakage at high R, add a discharge diode.

2. Practice and pitfalls

RC accuracy is ±10% at best - use it for soft delays, not precision timing.

3. Threshold-time table

ThresholdTime5s delayNote
0.632 (1τ)τ5sCommon
0.865 (2τ)2τ10sStable zone
0.950 (3τ)3τ15sNear full
0.5000.69τ3.5sHalf point
0.9002.3τ11.5sHigh threshold
0.9904.6τ23sPoor precision

4. Notes

Apply the points above to RC charging time constant in power; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 14048.11, IEC 60384 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Trusting ideal capacitor values
② Megohm-R networks with leaky caps
③ No discharge path between cycles

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.