Why bulb brightness changes in a series circuit

Why does one bulb glow and the other stay dim in series, and why does the lower-wattage lamp win? This page works the numbers so the series voltage-division rule becomes obvious.

1. How it works

Two identical bulbs in series split the supply voltage, and since P = U²/R, half the voltage means a quarter of the power: two 220V 40W lamps in series on 220V dissipate only about 10W each. Add more lamps and each gets dimmer - a string of three leaves each lamp with one ninth of rated power, barely a red filament.

2. Practice and pitfalls

The counter-intuitive case: a 40W lamp in series with a 100W lamp. Filament resistance falls as wattage rises - about 1210Ω for the 40W and 484Ω for the 100W. Same current flows, so P = I²R favours the higher resistance: the 40W lamp gets roughly 168V and 23W while the 100W lamp limps at 52V and 5.6W. One open filament kills the string; one shorted filament overvolts the rest.

3. Series bulb combinations quick table

Combination on 220VVoltage per lampPower per lampObservation
Two 40W in series110V eachAbout 10W eachMuch dimmer than solo
Three 40W in series73V eachAbout 4.4W eachDark red filament
40W + 100W series168V / 52V23W / 5.6WThe 40W is brighter
One 40W shortedOther lamp 220VOther lamp 40WShorted lamp stays dark
One filament openOpen lamp sees 220VAll 0WString dead, locates fault
Ten 15W in series22V eachAbout 0.15W eachFairy-light glow

4. Notes

Rule of thumb: in series the higher resistance wins. The lamp with the highest terminal voltage is either the open one or the victim of a neighbour shorted across. This locates faults in old fairy strings in one measurement.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Lamp and circuit fundamentals per GB/T 10681; circuit conventions per GB/T 4728. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Parallel intuition applied to series:in series the larger resistance wins, the opposite of parallel
② Leaving a shorted lamp in the string:the rest run overvoltage and burn one by one
③ Measuring bare lamp holders live:any point of a series string can sit at 220V

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.