A single-phase winding alone produces a pulsating field and zero starting torque. This page explains how the auxiliary winding and capacitor create rotation, compares the three classic split-phase schemes, and lists the capacitor traps.
The main winding alone yields a pulsating field, so the rotor sees no net torque at standstill. Adding an auxiliary winding displaced 90 electrical degrees in space, and shifting its current in time, synthesises a rotating field. Where the two pulsating fields overlap with the right phase offset the rotor develops starting torque. Windings that drop out after start are start windings; those left in circuit continuously are run windings.
Resistance split-phase uses a fine-wire auxiliary coil with 30 to 40 degrees of current phase shift, giving 1 to 1.6 times rated starting torque for small fans, with a centrifugal switch cutting out at 75 to 80 percent of rated speed. Capacitor-start inserts 50 to 400 microfarads to approach 90 degrees shift and 2.5 to 3.5 times torque for compressors. Permanent-split-capacitor motors run with 2 to 40 microfarads for smooth quiet operation, while dual-capacitor types use one capacitor each for start and run.
Start capacitors are short-time rated: wired permanently they swell and burst within minutes, especially electrolytic types. Run capacitors must be non-polarised film types rated 450 V or more, never electrolytics. Capacity loss beyond 10 percent already hurts starting torque, so measure with the capacitance range and compare to the marking. A welded centrifugal switch keeps the start winding energised and burns it, so inspect the switch and capacitor before rewinding any burned auxiliary coil.
| Type | Phase shift | Start torque | Typical duty |
|---|---|---|---|
| Resistance split | 30~40 deg | 1~1.6 of rated | Small fans, appliances |
| Capacitor start | Near 90 deg | 2.5~3.5 of rated | Compressors, pumps |
| Permanent split | Near 90 deg | 0.3~0.6 of rated | Ceiling fans, washers |
| Dual capacitor | Near 90 deg | 2~3 of rated | Water pumps, farm duty |
| Shaded pole | Not adjustable | Below 0.5 of rated | Micro motors, meter fans |
Diagnosis order: measure the capacitor first, then the centrifugal switch, before blaming the winding. Replace capacitors with identical rating and voltage; oversizing looks stronger but pushes auxiliary current past design and shortens insulation life.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 12350 for small motor safety requirements and GB/T 2693 for capacitor specifications. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.