Limit switches in automatic door control circuits

Open, close, slow down and reverse: an automatic door lives on its limit switches. This page walks the control logic of sliding doors and the safety design of lift landing-door locks.

1. How it works

An industrial sliding door typically runs three limit switches: fully-open, fully-closed and a deceleration limit before each end. The chain is simple: close command picks the closing contactor, the door runs, the decel switch drops it to low speed, the closed switch releases the contactor. Anti-pinch comes from a safety edge or light curtain wired into the closing path to force reversal. The up and down contactors cross-lock through each other NC auxiliaries, and a PLC implementation must keep the same software interlock.

2. Numbers and practice

Lift landing-door locks are the highest safety grade for limit switches: every landing carries a lock switch proving closure and locking, all wired in series into the safety circuit, so the car cannot start or must stop with any door open. Contacts must be positively driven open, held by the mechanical position of the lock rather than by a spring, so a welded contact cannot let the car run with doors open, and GB/T 7588 governs ratings and creepage. Bypassing the door-lock circuit is the leading cause of lift fatalities and is forbidden without exception.

3. Pitfalls and fixes

Field faults concentrate in the switch-and-cam system: water ingress despite ratings, loosened cams, oxidised contacts. Tune the deceleration distance to door speed, about 0.3 to 0.5 m at 0.5 m per second, filter the limit signal against bounce, and align both sides of double doors within 20 mm. After any switch change, run the door at least ten full cycles and test the anti-pinch edge with a test rod, because that test guards people directly.

4. Automatic door switch configuration

SwitchLocationFunctionFailure result
Open limitFully openStop and lock openMotor stall burnout
Close limitFully closedStop, signal closedNot-closed alarm
Decel limit0.3~0.5 m before endSlow down earlyHigh-speed impact damage
Safety edgeDoor bottom railReverse on pinchInjury accident
Light curtainDoor aperture sidesZone detectionNuisance trips
Door lock switchLanding door lockLift start interlockMajor safety incident

5. Notes

Quarterly, run every door through full cycles and measure closed contact resistance below 0.1 ohm; inspect landing locks on the statutory schedule; and after replacing any switch, physically test the anti-pinch edge, a test that directly protects people.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 14048.5 for position switches, GB/T 7588 for lift safety and IEC 60204-1 for machinery control. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Bridging the lift door-lock circuit during repairs: cars have cut people down with doors open, so the safety loop is never bypassed
② Ignoring a dead open-limit switch: the motor stalls at times rated current until thermal trips give way to a burned motor
③ Setting the decel point too close: the door slams the limit at speed and the drive mechanism fatigues at half life

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.