The limit switch is the original sensor, switching circuits by mechanical contact. This page covers plunger, roller-lever and cross-roller types, the operating characteristics, and installation that gets it right first time.
Plunger types travel 1 to 3 mm with high precision for positioning and counting; roller-lever types suit side-swiping contact with 10 to 30 mm of travel; cross-roller levers act in both directions for reversing duty. Inside every one sits a snap-action contact: the leaf flips in under a millisecond, with a definite hysteresis of 1 to 3 mm between operate and release that stops chattering when the striker hovers at the edge.
Key ratings: operating force from 0.5 to 5 N, overtravel reserve of 20 to 30 percent, mechanical life beyond 10 million cycles and electrical life of 0.5 to 1 million at 10 A switching a 220 V contactor coil. Below about 0.4 mm per minute of striker speed a hit cannot flip the contact reliably, so choose a low-force microswitch or move to a proximity sensor; above 2 m per second use a roller head with proper wrap of the cam.
Installation in three moves: operate the striker by hand through the full stroke; set the cam so overtravel remains rather than bottoming out, which bends levers; lock and run ten cycles listening for consistent click. Typical failures are welded contacts from unsuppressed inductive loads, water ingress below IP67 in wet spots, and bent levers from drifting cam paths. Verify operate and release points with a meter, and reposition the cam rather than bending the switch when the point drifts beyond 0.5 mm.
| Type | Travel | Force | Typical duty |
|---|---|---|---|
| Plunger | 1~3 mm | 1~5 N | Precise positioning, counting |
| Roller lever | 10~30 mm | 0.5~2 N | Conveyor side detection |
| Cross roller | 10 mm each way | 0.8~2.5 N | Reversing duty |
| Microswitch | 0.5~2 mm | 0.1~0.6 N | Very small travel |
| Spring wire lever | Angular trigger | 0.3~1 N | Soft collisions |
| Heavy roller | 15~45 mm | Above 5 N | Heavy carriage stops |
Calibrate the trip point of every critical limit switch annually and log it; adjust the cam when wear moves the point beyond 0.5 mm. Stock spares by head type and prefer models with replaceable microswitch inserts to cut the spare-parts bill.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 14048.5 (IEC 60947-5-1) for position switches and IEC 60204-1 for safety-related functions. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.