Can the neutral be thinner than the phases, and when must it be thicker? This page gives the three sizing rules and the harmonic mechanism that can push neutral current past phase current.
Three rules govern the neutral. For copper phase conductors up to 16 mm² the N line matches the phase. For larger phases in balanced, low-harmonic circuits the N may be half the phase section but not below 16 mm². In harmonic-rich circuits such as dense LED lighting, rectifiers and drives, the neutral must be at least equal to, and often 1.5 to 2 times, the phase section, because triplen harmonics add arithmetically in the neutral.
The mechanism: fundamental currents of a balanced three-phase set sum to zero, but third-harmonic components share the same phase in all three lines and therefore add. A measured office riser carrying 80 A per phase showed 115 A in the neutral at 45 percent distortion with a half-section neutral overheating. Fixes: full-section neutrals, third-harmonic filtering, or delta-star isolation. Diagnose with a true-RMS clamp meter, measuring phases and neutral; a neutral current above the phases proves the addition.
Protection and installation: in TN systems the neutral carries no separate fuse, because an open neutral feeds phase voltage through loads to the broken side; four-pole breakers switch the neutral with the phases. Run N with its phases in the same conduit, crimp joints properly, since a heated neutral joint is a classic fire starter, and keep PE and N separated in TN-S. Single-phase 220 V circuits always take an equal-section neutral, no exceptions.
| Circuit case | N section | Basis | Note |
|---|---|---|---|
| Single-phase 220 V | Equal to phase | Currents equal | No exceptions |
| Balanced, low harmonics | Half of phase, ≥16 mm² | Small imbalance | Phases above 16 mm² |
| Phases ≤16 mm² | Equal to phase | Mechanical and thermal | Copper circuits |
| Harmonic-rich | At least phase, 1.5~2x | Triplen addition | LED, dimmers, rectifiers |
| TN-C PEN | Equal to phase | Also protective | Never switched |
| Four-pole breaker | N switches with phases | No separate N fuse | Prevents open-neutral damage |
Measure true-RMS neutral current on lighting and IT risers and queue any circuit where N exceeds phase for rectification. Thermally scan neutral terminals yearly, and specify full-section neutrals for office and machine-room lighting in new designs.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB 50054 for LV distribution design and the GB/T 16895 series for conductor selection. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.