No-load and locked-rotor tests for three-phase induction motors

You can profile an induction motor without dismantling it: the no-load test separates iron and friction losses, the locked-rotor test gives the short-circuit parameters. This page covers procedure, calculations and pass criteria, useful before and after a rewind.

1. How it works

Run the motor uncoupled at rated voltage and frequency. The input power P0 splits into stator copper loss 3·I0²·R1, iron loss and friction-plus-windage. Step the voltage down from 1.2 times rated in five to seven points, plotting P0 − 3·I0²·R1 against U². Extrapolating the straight line to U² = 0 gives the mechanical loss as the intercept; the rest is iron loss. No-load current should sit at 20 to 50 percent of rated; above 50 percent points at an oversize air gap or too few turns.

2. Numbers and practice

For the locked-rotor test, lock the shaft, start from 0.2 to 0.3 of rated voltage and raise it until the current nears rated. With slip equal to 1 the machine behaves like a shorted transformer: Rk = Pk/(3·I²), Zk = U/(√3·I) converted to phase values, Xk = √(Zk² − Rk²). From these you estimate the starting current multiple. Abnormally high current suggests too few turns or a large air gap; low current can mean cracked rotor bars raising rotor impedance.

3. Pitfalls and fixes

Use both tests for acceptance and diagnosis. Compare no-load current, no-load loss and locked current against the nameplate; no-load loss 20 percent above sister machines flags poor core quality or eccentric assembly. Three-phase no-load current imbalance beyond 10 percent, or current ripple while hand-turning the rotor, indicts the winding or broken bars. Keep each locked run under 10 seconds and let the winding cool between runs.

4. Interpreting no-load and locked-rotor data

ItemNormal rangeHigh meansLow means
No-load current20~50% of ratedLarge gap, few turnsWeak flux design
No-load lossOn par with sistersPoor core, eccentricityMetering or wiring error
No-load imbalanceUnder 10%Winding turn faultSupply or meter issue
Locked currentDesign multiple ±20%Few turns, big gapPossible broken bars
Locked torque1~2.2 of ratedOver-saturated designRotor circuit defect
Short-circuit RkMatches winding tempBar contact resistanceMeasurement error

5. Notes

Keep a test card for every critical motor with no-load current, no-load loss and locked current before and after repair; drift on the card is an early warning. Make sure the rotor is mechanically locked, not just roped, before energising.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1032 for three-phase induction machine test methods and IEC 60204-1 for machinery safety. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Jumping straight to full locked-rotor voltage: current exceeds twice rated and the winding smokes within tens of seconds, always ramp in steps
② Condemning the winding on current imbalance alone: confirm the supply itself is balanced within 2 percent first
③ Roping the rotor instead of locking it: full starting torque snaps the rope and the rotor kicks loose, use a mechanical lock

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.