Servo positioning accuracy is set by mechanics first and electronics second. This page quantifies each contributor from ball screw grade to thermal growth, then lists the fixes that actually move the number.
Accuracy comes from encoder resolution, mechanical transmission error, control dead zones and the environment. A 5 mm lead screw with a 23-bit encoder resolves about 0.6 nanometres on paper, yet real machines hold only a few micrometres. The gap is made of screw lead error, which is 50 µm per 300 mm for C7 ballscrews against 18 µm for C5, coupling and key backlash, bearing play, and thermal growth of about 12 µm per metre per 10 degrees C. The encoder cannot rescue what the mechanism loses.
Electrical contributors in order: overshoot and ringing during the last ten percent of travel, set by the deceleration profile; stick-slip dead zone when static friction exceeds dynamic; wrong electronic gear ratio mismatching command units to mechanics; and occasional pulse loss from poor shield grounding. A large inertia ratio lowers bandwidth and drags out settling. The drive scope trace of following error during settling tells you instantly whether you face gain tuning or mechanics.
Practical upgrades: choose C5 screws, use anti-backlash nuts and gears, shorten the transmission chain, and fit a linear scale for full closure, reaching about ±5 µm. Electrically, apply feedforward, friction compensation, and a pitch-error compensation table calibrated with a laser interferometer, cutting systematic error by 70 percent. Warm the machine up 30 minutes before precision work, and accept it with laser measurement per standard rather than a single dial gauge point.
| Factor | Typical size | How to detect | Countermeasure |
|---|---|---|---|
| Screw lead error | C7: 50 µm/300 mm | Laser interferometer | Pitch table or C5 screw |
| Backlash | 5~30 µm | Reversal dial comparison | Preloaded anti-backlash |
| Thermal growth | 12 µm/m per 10 C | Cold versus hot measurement | Warm-up or cooling control |
| Overshoot | 1~5 command units | Drive scope trace | Feedforward and gains |
| Stick-slip dead zone | Friction related | Low-speed feed observation | Friction compensation |
| Encoder pulse loss | Sporadic, µm level | Shielding and grounding check | Shielded pair, single-point earth |
Acceptance order: mechanics first, electrics second; static before dynamic. Mechanical accuracy is the ceiling, and compensation only walks under it. Full closure is the thorough answer but demands Abbe error control when mounting the scale, or the result gets worse than half-closed.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 17421.2 for CNC positioning accuracy tests and GB/T 12668 for servo drive requirements. Always check the device datasheet and the product design file for ratings and derating.