When one capacitor cannot clean the switching ripple, one inductor buys another 30dB. This page covers the π filter principle, cutoff math, and how to tame the resonant peak.
A π filter places a bulk capacitor at the source, an inductor in series, and a second capacitor at the load. The front capacitor absorbs fast current edges locally, the inductor blocks high frequencies, the rear capacitor delivers clean power. A single LC stage rolls off at 40dB per decade - twice the slope of a bare capacitor.
Worked example: a 100kHz buck wants sub-20mV ripple. With L = 100µH and C = 100µF the cutoff is 1.6kHz; 100kHz sits 60 times above it, so theoretical attenuation approaches 70dB and a parasitic-limited 35dB still turns 100mV into about 2mV. Pick the inductor at 1.5 times load current (watch Isat and Irms), low-ESR capacitors with 50 percent ripple-current margin. Suppress the resonance with 0.1 to 0.5Ω in series with the inductor - an undamped LC peak can amplify ripple near cutoff instead of cutting it. Layout: keep the two capacitor grounds separate; verify by measuring ripple before and after with a scope.
| Switching frequency | L value | C value | Cutoff |
|---|---|---|---|
| 20kHz | 470µH | 220µF | 0.5kHz |
| 50kHz | 220µH | 100µF | 1.1kHz |
| 100kHz | 100µH | 100µF | 1.6kHz |
| 300kHz | 33µH | 47µF | 4.0kHz |
| 500kHz | 22µH | 22µF | 7.2kHz |
| 1MHz | 10µH | 10µF | 15.9kHz |
Workflow: cutoff at one-twentieth to one-fiftieth of the switching frequency, inductor at 1.5 times load, low-ESR caps, damping resistor ready. After assembly, compare ripple on both sides - if the gain is short, suspect saturation first, ground routing second.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Capacitor specification per GB/T 2693 (IEC 60384-1); supply EMC filtering per the IEC 61000 series and GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.