Diodes do more than rectify: a reverse-biased varactor is a voltage-tuned capacitor, a reverse-biased photodiode turns light into current. This page covers both, with parameters and wiring traps.
A varactor exploits the voltage-dependent junction capacitance: a BB910 offers about 24pF at 0.5V reverse bias falling to 2.6pF at 8V - nearly a ten-to-one tune. Feed the tuning voltage through a 100kΩ isolation resistor, filter it hard (ripple modulates the oscillator directly), and place two varactors back-to-back in large-signal tanks to cancel nonlinearity.
A photodiode runs reverse-biased and produces a photocurrent linear with light level - microamps, so a transimpedance amplifier (op-amp plus feedback resistor) converts it to voltage. Key numbers: responsivity near 0.5A/W, dark current in nanoamps doubling every 10 degrees, PIN types responding in nanoseconds. Choose photodiodes for linear measurement, phototransistors for cheap switching (hundreds of times more sensitive, slower, nonlinear), and integrated 38kHz receiver modules for remote controls. Never forward-bias a photodiode - it does not emit, it burns.
| Type | Bias | Key parameter | Typical use |
|---|---|---|---|
| Varactor BB910 | Reverse 0.5~8V | 2.6~24pF | Electronic tuning, VCO |
| Varactor BB112 | Reverse 1~28V | 14~540pF | AM tank circuits |
| PIN photodiode | Reverse 5~20V | 0.5A/W, nA dark current | Optical power, fibre RX |
| IR receiver module | Supply 2.7~5.5V | 38kHz integrated | Remote control |
| Phototransistor | Reverse/collector bias | 100x photodiode sensitivity | Photo switches, counters |
| LED | Forward 1.8~3.2V | Do not confuse with photodiode | Indication, IR transmit |
Motto: varactors need a clean bias, photodiodes need shielding. Linear measurement takes a photodiode, switching takes a phototransistor, remotes take an integrated module - do not improvise from discretes.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Semiconductor device classification per the IEC 60747 series; optocoupler devices per GB/T 15651. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.