DC motor starting methods and starting resistor calculation

Direct-on-line starting of a DC motor draws 15 to 20 times rated current because there is no back-EMF yet. This page explains the physics, gives a step-by-step resistor calculation, and shows when to short out each step.

1. How it works

At standstill the back-EMF Ea = Ce·Φ·n is zero, so only the small armature resistance Ra limits the inrush. With Ra of a few tenths of an ohm, applying full 220 V would draw 15 to 20 times rated current, burning brushes and shocking the shaft train. The fix is to limit inrush to roughly 2 to 2.5 times rated current by inserting resistance in the armature circuit.

2. Numbers and practice

A practical scheme uses two to four resistor steps. Size the total resistance R1 = U/I1 − Ra with I1 at twice rated current, then short out each step when the current falls back to about 1.2 times rated, giving a current ratio of about 1.67 per step. For a 220 V, 40 A motor with Ra = 0.5 Ω the total comes to 2.25 Ω, split across three steps near 0.85, 0.5 and 0.9 ohm.

3. Pitfalls and fixes

Cut-out can be current-controlled, using accelerating current relays, or time-controlled with 0.5 to 3 s delays per step. Current control follows the load better; timing is simpler to wire. Starting resistors are short-time rated, so never leave them in circuit as speed regulators, and verify the allowable starts per hour for frequent duty.

4. DC motor starting methods compared

MethodPower rangeInrush multipleNotes
Direct on lineBelow 0.5 kW15~20 timesSmall motors only
Stepped armature resistorSmall to medium2~2.5 timesClassic, short-time resistor
Reduced voltageLarger machinesAbout 2 timesNeeds adjustable DC source
Field first, armature laterGeneralWithin 2 timesEnergise field before armature
Starting resistor as speed regulatorForbiddenUnlimitedThermal rating too small

5. Notes

Remember the order: field on first, then armature, always through resistance. Measure Ra by the voltmeter-ammeter drop method, size the total for twice rated current, cut in two or three steps at 1 to 2 s intervals, and consider the job done when the ammeter swings between 1.2 and 2 times rated.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1311 for DC machine testing and IEC 60204-1 for machinery electrical safety. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Closing the armature before the field is established: with no flux there is no back-EMF and the inrush instantly wrecks the commutator
② Leaving starting resistors in circuit for speed control: they are short-time rated, glow red within minutes and burn open
③ Cutting steps too early: the current surges past 3 times rated again and hammers the gearbox and couplings

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.