An idle adapter still burns watts - a hundred of them quietly cost hundreds of kWh a year. This page locates the no-load losses and shows how burst mode gets below 0.1W.
Four loss sources at no load: the high-voltage startup resistor (470kΩ on a 310V bus burns 0.2W continuously - the biggest chunk in older designs), the PWM controller and auxiliaries, the stability dummy load, and switching plus core losses that continue at full frequency. A typical flywheel adapter idles at 0.3 to 0.5W, which is why efficiency regulations (CoC Tier2, DoE Level VI) push no-load below 0.075 to 0.1W.
Burst mode is the main fix: when the output drifts high the controller stops switching, the output coasts on its capacitors, and a few pulses refresh it when the valley is reached - average switching drops to a few hertz and no-load loss to 0.05 to 0.1W. Support changes: replace the startup resistor with an internal high-voltage startup current source, make the dummy load switched-in only under light-load detection. Side effects to manage: output ripple rises to a few hundred millivolts (follow with an LDO for sensitive loads), transient response slows, and burst in the audio band can make the transformer sing - detune the thresholds and impregnate the core. On the production line, average power readings over ten seconds; instantaneous sampling during the sleep window fails good units.
| Measure | Saving | Method | Cost |
|---|---|---|---|
| Burst mode | 0.2~0.4W | Feedback-threshold gating | More ripple, slower response |
| HV startup source | 0.15~0.2W | Integrated startup FET | Chip selection |
| Switched dummy load | 5~25mW | Connect on light-load detect | Extra logic |
| Standby frequency foldback | 10~50mW | Frequency back circuit | Transformer margin |
| Zero-load shutdown | All standby power | Sleep on no load | Wake-up latency |
| Sync rectifier sleep | 10~30mW | Disable at light load | Slight light-load loss |
Order of attack: measure the loss breakdown first, then choose burst mode or a chip with an integrated startup source. Verify with a ten-second averaged power reading - never with an instantaneous sample.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Standby power measurement per IEC 62301; switch-mode supply safety per GB 4943.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.