Speed that wanders or sags under load on a DC motor points to the field circuit, the armature circuit or the feedback loop. This page gives a shortest-path procedure with meter points and numeric criteria to pin down the root cause in half an hour.
Speed follows n = (U − Ia·Ra)/(Ce·Φ), so both sides of the fraction matter. Field circuit trouble such as a dirty rheostat or a loose joint makes the flux fluctuate and shows up even at no load, with the field ammeter needle swinging. Armature side trouble such as brush contact problems shows up as load-dependent sag with a fluctuating armature current. Check field stability first, then armature.
The measuring sequence: first watch the field current, investigate joints and the rheostat if it wavers beyond ±5 percent; second measure armature voltage and current, allowing for the normal Ia·Ra drop with load and worrying when sag exceeds 10 percent; third grade the brush sparking, since anything above grade 2 makes the contact drop unstable; fourth inspect the tacho or encoder feedback, where broken shielding or a slipping coupling causes rhythmic hunting.
Field joints cause over 40 percent of unstable speed cases, and the rheostat slider is the usual culprit. Brush pressure imbalance produces a ticking that follows speed. Most critical: never let a shunt motor lose its field, because on residual magnetism alone the speed can run past twice rated, throwing armature end windings. Always fit field-loss protection.
| Check item | Method | Normal range | Points to |
|---|---|---|---|
| Field current | Series ammeter | Wobble under ±5% | Loose field joints, turn faults |
| Armature U and I | Loaded drop test | Drop follows load | Brush contact trouble |
| Brush sparking | Visual grading | Grade 1 or less | Pressure, runout, film |
| Speed stability | Continuous tacho read | Within ±2% | Feedback or load swings |
| Feedback device | Scope on pulses | Even pulses, no drops | Shield damage, slipping coupling |
| Load side | Uncouple and idle | Speed settles at once | Load issue, not the motor |
The walk order is: field stability, brush sparking, then feedback integrity. Uncoupling the load is the fastest split test: steady idle but drifting under load sends you to the armature and load, while idle drift sends you straight to the field circuit.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1311 for DC machine operation and tests, and IEC 60204-1 for protective provisions on machinery. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.