Same bridge, very different damage: on a 5V rail the two conducting diodes eat 28 percent; on 3.3V it is worse. This page runs the numbers and gives the Schottky and synchronous fixes.
Silicon diodes drop 0.6 to 0.7V (power types 0.9 to 1V), Schottky types 0.3 to 0.45V. A bridge always has two devices in the path, so a 5V supply loses 1.4V - 28 percent of the output - while a 12V rail loses only 12 percent. The lower the voltage, the uglier the arithmetic.
Worked example, 5V at 5A: 1N5408 bridges dissipate 2×0.9×5 = 9W just rectifying; SR540 Schottkys cut that to 5W; a synchronous MOSFET at 10mΩ drops it to 0.25W - three percent of the original. Below 3.3V at any real current, synchronous rectification is the only serious option. Field notes: Schottky leakage climbs an order of magnitude at 100 degrees junction, so check the thermal neighbourhood; rate rectifiers at twice the average current; and never fit a 1N4007 in a 3A path - it cooks. A 40V Schottky in a 24V bridge dies on the first surge.
| Device | Forward drop | Rectifier loss | Suitable for |
|---|---|---|---|
| 1N5408 silicon | 0.9V at 5A | 9W | High voltage, not LV |
| SR540 Schottky | 0.5V at 5A | 5W | 5V-class outputs |
| MBR20100 Schottky | 0.4V at 5A | 4W | Low voltage, high current |
| Synchronous MOS 10mΩ | 0.05V equivalent | 0.25W | Mandatory above 3.3V/5A |
| 1N4007 silicon | 0.7V at 1A | Burns when overloaded | Signal circuits only |
| Ideal-diode controller | 0.02V equivalent | 0.1W | Premium LV designs |
Motto: the lower the rail, the lower the drop must be - go synchronous below 3.3V; give Schottkys twice the voltage rating and check hot leakage; rate rectifiers at twice the average current and stop putting 1A parts in 3A paths.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Semiconductor device ratings per the IEC 60747 series; power supply safety per GB 4943.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.