For the same shaft power a single-phase motor costs more, runs hotter and draws more current than a three-phase unit. This page puts numbers on efficiency, power factor, starting torque and overload margins to guide selection and repair decisions.
At equal power, single-phase machines trail three-phase by 5 to 15 percentage points in efficiency: a 1.1 kW three-phase motor reaches 79 to 82 percent while a capacitor-run single-phase of the same rating manages 65 to 72 percent. The losses come from the negative-sequence field component that produces braking torque and stray loss, from copper loss in the auxiliary circuit, and from design compromises imposed by starting requirements. Below about 120 W the gap narrows.
Power factor tells the same story: 0.75 to 0.85 for three-phase against 0.6 to 0.75 for single-phase. Starting torque differs more sharply: three-phase direct starting delivers 1 to 1.5 times rated, resistance-split single-phase 1 to 1.6 times at 5 to 7 times current, and capacitor-run types only 0.3 to 0.6 times, which is why compressors need capacitor-start designs. Overload margins sit near 1.8 to 2.2 times for three-phase and 1.6 to 1.8 for single-phase.
Selection practice: choose three-phase whenever a three-phase supply exists, and reserve capacitor-run or dual-capacitor machines for single-phase premises. Driving a single-phase motor from a VFD as a phase converter is risky, since the negative-sequence component grows and the capacitor circuit can resonate; keep it under half load and short duration. Remember a three-phase motor that loses a phase behaves like a poor single-phase machine: torque collapses and current climbs 50 to 100 percent until the relay trips.
| Metric | Three-phase | Single-phase cap-run | Root cause |
|---|---|---|---|
| Efficiency at 1.1 kW | 79~82% | 65~72% | Negative sequence, copper loss |
| Power factor | 0.75~0.85 | 0.6~0.75 | Field ellipticity |
| Starting torque | 1~1.5 of rated | 0.3~0.6 of rated | No self-starting ability |
| Start current | 5~7 of rated | 4~6 of rated | Start circuit impedance |
| Overload margin | 1.8~2.2 times | 1.6~1.8 times | Cooling and stray loss |
| Speed control | Mature VFD | Voltage or taps, narrow | Field structure |
On repair economics, rewinding a burned single-phase motor costs 60 to 80 percent of a new unit, so replace rather than rewind. Every three-phase motor must carry phase-loss protection; half an hour of single-phasing usually writes off the winding. Check frame sizes when substituting, since single-phase frames run larger.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 755 for efficiency determination and GB/T 12350 for small motor safety. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.