Impedance, admittance and phasor calculation in AC circuits

R, L and C cannot be added directly in an AC circuit - phase hides the trap. This page covers reactance formulas, phasor construction and how to spot a resonance before it bites.

1. How it works

Inductive reactance XL = 2πfL rises with frequency; capacitive reactance XC = 1/(2πfC) falls. At 50Hz, 100mH gives 31.4Ω and 100µF gives 31.8Ω. The magnitudes cannot simply be added: resistor voltage is in phase with current, inductor voltage leads by 90 degrees, capacitor lags by 90. Combine as Z = √(R² + (XL−XC)²), with XL and XC opposing each other - the key to both resonance and power-factor correction.

2. Practice and pitfalls

Worked example: R = 30Ω in series with XL = 40Ω gives Z = 50Ω at a 53 degree angle. On 220V the current is 4.4A lagging 53 degrees, so P = 580W, Q = 774var, S = 968VA, power factor 0.6. When XL equals XC the circuit resonates: impedance collapses to R, component voltages reach Q times the supply, and capacitors fail - so scan the harmonic background before adding compensation caps, and remember a multimeter on a coil reads impedance magnitude, not DC resistance.

3. AC behaviour of R, L, C quick table

ElementImpedanceValue at 50HzPhase relation
Resistor RZ = R30Ω is 30ΩVoltage in phase
Inductor LZ = j2πfL100mH → 31.4ΩVoltage leads 90°
Capacitor CZ = −j/(2πfC)100µF → 31.8ΩVoltage lags 90°
RL series√(R²+XL²)30Ω + 100mH → 50ΩCurrent lags 53°
RC series√(R²+XC²)30Ω + 100µF → 44ΩCurrent leads 47°
R+L+C series√(R²+(XL−XC)²)Near resonance aboveCurrent can surge

4. Notes

Practice: compute reactances first, then combine - never feed an ohmmeter reading into AC formulas. Before switching in compensation capacitors, sweep the 3rd and 5th harmonic background and steer clear of the resonant point.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: AC calculation and symbol conventions per GB/T 4728; equipment design safety per GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Feeding impedance magnitude into DC-style Ohm law:current comes out wrong and cable sizing follows
② Blind capacitor switching:landing on the resonant point surges current and bursts cans
③ Ohmmeter readings as AC impedance:the reactive part is simply invisible

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.