Motors from 200 kW to 2 MW on mine hoists and main fans are typically 6 kV or 10 kV wound-rotor machines. This page covers rotor-resistance starting, insulation test practice and the maintenance points unique to high-voltage machines.
Wound rotors dominate at this power level because direct starting would collapse the supply. A frequency-sensitive rheostat in the rotor circuit automatically varies its impedance as rotor frequency falls during run-up, then a contactor shorts the rotor rings at full speed. Starting current is held to 2 to 2.5 times rated while starting torque stays above 1.2 times, far gentler than a comparable cage machine on line.
Insulation is usually class F epoxy-mica. Preventive testing uses a 2500 V megger on 6 kV machines with a hot-state threshold near 6 MΩ, and any sharp fall schedules a dry-out. Protection goes beyond overload: differential protection above 2 MW, earth-fault protection, and stator RTDs embedded in slots, at least two per phase, alarming at 140 C and tripping at 150 C. In gassy mines the terminal boxes must keep their flameproof faces intact.
Field maintenance focuses on the slip rings and brushes: monthly checks for brush length above 20 mm and pressure at 15 to 20 kPa, ring runout within 0.05 mm, and immediate dressing if sparking appears. External rotor resistor contacts oxidise in dust and cause weak starts. Duty and standby fans must be rotated in service with periodic changeover tests, and anti-condensation heaters energised whenever the machine is stopped, especially in humid seasons.
| Item | LV motor | HV motor | Note |
|---|---|---|---|
| Insulation threshold | 1 MΩ per kV cold | Above 6 MΩ hot at 6 kV | 2500 V megger required |
| Starting method | DOL or soft start | Wound rotor + rheostat | Limits supply shock |
| Protection | Overload, short circuit | Differential, earth, temp | Scaled by rating |
| Temperature sensing | Frame estimate | Slot RTD Pt100 | Two per phase minimum |
| Brushes and rings | None | Monthly inspection | Wound rotor only |
| Moisture control | Usually none | Heaters when stopped | Anti-condensation |
Keep a monthly checklist for each HV motor covering brush length, ring temperature and heater status. Log insulation resistance every six months; a fall beyond 30 percent schedules drying before a breakdown forces your hand.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 755 for ratings and GB/T 50150 for handover test practice on HV equipment. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.