Two 470µF capacitors can differ tenfold in ESR, and so will their output ripple. This page shows how ESR drives ripple, heating and loop stability, and how to pick and check capacitors in the field.
A real capacitor behaves like an ideal one in series with a resistance: the ESR. Aluminium electrolytics run from tens of milliohms to a few ohms, solid polymer types sit at 10 to 30mΩ. Ripple current across this resistance produces the sharp I×ESR component of output ripple and heats the part. ESR also climbs steeply when cold - several times higher at -20 degrees - which is why supplies fail to start in unheated workshops.
Numbers: on a 5V 2A buck with 1A peak-peak ripple current, a 100mΩ electrolytic adds 100mV of ripple while a 20mΩ solid cap cuts it to 20mV. Heating follows I²R; the resulting core temperature dries the electrolyte, ESR climbs three to five times, and ripple worsens in a loop that ends in protection trips. Excess ESR also upsets loop compensation, causing audible low-frequency oscillation. Diagnose aged parts in-circuit with an ESR meter: twice the datasheet value means replace.
| Capacitor type | Typical ESR | Strength | Caution |
|---|---|---|---|
| Standard aluminium electrolytic | 50mΩ~2Ω | Cheap, high capacity | Ages hot, ESR explodes cold |
| Low-ESR electrolytic | 18~50mΩ | Handles ripple current | Still temperature-limited life |
| Solid polymer | 10~30mΩ | Long life, stable when cold | Lower voltage ceiling, costlier |
| Ceramic MLCC | 1~10mΩ | Excellent at high frequency | capacitance drops under DC bias |
| Tantalum | 50~150mΩ | Small, stable | Fails shorted, risky on supplies |
| Film | 5~20mΩ | High voltage, stable | Bulky, great for snubbers |
Field motto: sharp ripple spikes, check ESR first; poor cold starts, aged electrolytics. An in-circuit ESR meter reads a part in seconds - far faster and more honest than a capacitance check.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Capacitor general specification per GB/T 2693 (IEC 60384-1); power supply safety per GB 4943.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.