Conveyors, winders and machine spindles load a drive in completely different ways. This page defines the three classic load families, shows how to identify them by measurement, and lists the sizing consequences of getting it wrong.
Constant-torque loads need the same torque at any speed with power rising with speed: belt conveyors, hoists, screw compressors and extruders. Constant-power loads trade torque against speed at near-constant power: winders holding tension as the roll grows, and machine spindles that cut hard and slow or finish fast. Fan and pump loads scale torque with the square and power with the cube of speed, so slowing 20 percent cuts power to 51 percent. Measure torque at several speeds and the family is obvious.
Sizing: for constant-torque duty cover the maximum load torque plus acceleration with 1.3 to 1.5 margin, and watch self-ventilated machines below about 20 r/min where cooling collapses, requiring forced ventilation or a bigger frame. Constant-power sizing fixes the motor by the torque needed below base speed, with field weakening typically limited to twice base speed. Fans and pumps size the converter on rated current without oversizing, operated at the efficient part of the curve.
Typical misjudgements: treating a winder as constant torque trips the drive at large roll diameter at low speed; a spindle stalling in heavy low-speed cuts means the constant-power band reaches too far down, so add a gearbox or pick a wider constant-torque range; and a fan retrofit that saves less than promised usually has dampers still throttling. Half a day measuring the load curve beats a hundred-fold rework later.
| Family | Torque-speed law | Typical duty | Sizing note |
|---|---|---|---|
| Constant torque | T flat, P follows speed | Conveyor, hoist, extruder | 1.3~1.5 margin, cooling at low speed |
| Constant power | T inverse to speed | Winder, spindle | Size below base speed, weaken to 2x |
| Fan and pump | T with speed squared | Centrifugal fan, pump | No converter oversizing |
| Combined | CT low, CP high | Paper section drives | Check torque per band |
| Potential energy | Four-quadrant | Lifts, cranes | Braking unit mandatory |
| Shock load | Violent torque swings | Crushers, presses | Peak torque and flywheel check |
Measure first, then select; draw the curve before the capacity. Where the family is unclear, size conservatively as constant torque, half a frame up rather than half a frame down.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 12668 for adjustable-speed drive sizing and GB/T 755 for motor ratings. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.