How does a clutch transmit torque without contact? This page explains the eddy-current force mechanism, the relation of slip and field current to torque, and where the split clutch differs from the integrated slip motor.
The clutch consists of a steel drum on the driving side and a salient-pole field assembly on the driven side, with no mechanical contact. With no field current the poles are inert and the drum spins free. Energised with DC, the field magnetises the poles, the rotating drum cuts the flux, eddy currents are induced in the drum wall, and the interaction drags the poles around with the drum. Output must lag input, since with zero slip there is no induced EMF and no torque, unlike a friction clutch.
At a given field current, larger slip means stronger induced EMF, larger eddy currents and more torque, giving a drooping speed-torque curve; at a given slip, more field means more torque. Speed control therefore works by trimming field current from a thyristor supply of 0 to 4 A at 0 to 90 V DC, with tachometer feedback closing the loop for a 10:1 to 20:1 range. Slip power all becomes drum heat and efficiency approximates the output-to-input speed ratio, so the clutch suits square-torque fan and pump duty rather than sustained low-speed heavy torque.
The integrated YCT slip motor is simply this clutch built onto the driving motor; the separate clutch serves tension control and soft starting duties. Tension winding is its strength: trimming field current holds near-constant tension at low cost and high shock tolerance, though slower than vector-controlled alternatives. Select for at least 1.3 times maximum torque, insist on closed types in dust, and keep the 0.3 to 0.8 mm gap clean.
| Parameter | Typical value | Relation | Field meaning |
|---|---|---|---|
| Field current | 0~4 A at 90 V DC | Proportional to torque | The control handle |
| Slip | 10~50 percent common | More slip, more torque | Heat at low speed |
| Air gap | 0.3~0.8 mm | Affects excitation efficiency | Dust seizure risk |
| Speed range | 10:1 to 20:1 closed | Specification with feedback | Only 3:1 open loop |
| Steadiness | 2~3 percent | Closed-loop figure | Fine for tension work |
| Response | 0.2~1 s | Field inertia dominated | Not for fast servo work |
Avoid the clutch where the load lives below 70 percent of input speed, since efficiency tracks the speed ratio and heat becomes the issue; prefer a VFD there. Its value shows in tension control, cushioned starts and inertia smoothing, with gap cleanliness and brush upkeep as the maintenance core.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 21972 for eddy-current motor standards and GB/T 12668 for adjustable speed systems. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.