The principle of eddy-current slip clutch speed control

How does a clutch transmit torque without contact? This page explains the eddy-current force mechanism, the relation of slip and field current to torque, and where the split clutch differs from the integrated slip motor.

1. How it works

The clutch consists of a steel drum on the driving side and a salient-pole field assembly on the driven side, with no mechanical contact. With no field current the poles are inert and the drum spins free. Energised with DC, the field magnetises the poles, the rotating drum cuts the flux, eddy currents are induced in the drum wall, and the interaction drags the poles around with the drum. Output must lag input, since with zero slip there is no induced EMF and no torque, unlike a friction clutch.

2. Numbers and practice

At a given field current, larger slip means stronger induced EMF, larger eddy currents and more torque, giving a drooping speed-torque curve; at a given slip, more field means more torque. Speed control therefore works by trimming field current from a thyristor supply of 0 to 4 A at 0 to 90 V DC, with tachometer feedback closing the loop for a 10:1 to 20:1 range. Slip power all becomes drum heat and efficiency approximates the output-to-input speed ratio, so the clutch suits square-torque fan and pump duty rather than sustained low-speed heavy torque.

3. Pitfalls and fixes

The integrated YCT slip motor is simply this clutch built onto the driving motor; the separate clutch serves tension control and soft starting duties. Tension winding is its strength: trimming field current holds near-constant tension at low cost and high shock tolerance, though slower than vector-controlled alternatives. Select for at least 1.3 times maximum torque, insist on closed types in dust, and keep the 0.3 to 0.8 mm gap clean.

4. Slip clutch parameter relations

ParameterTypical valueRelationField meaning
Field current0~4 A at 90 V DCProportional to torqueThe control handle
Slip10~50 percent commonMore slip, more torqueHeat at low speed
Air gap0.3~0.8 mmAffects excitation efficiencyDust seizure risk
Speed range10:1 to 20:1 closedSpecification with feedbackOnly 3:1 open loop
Steadiness2~3 percentClosed-loop figureFine for tension work
Response0.2~1 sField inertia dominatedNot for fast servo work

5. Notes

Avoid the clutch where the load lives below 70 percent of input speed, since efficiency tracks the speed ratio and heat becomes the issue; prefer a VFD there. Its value shows in tension control, cushioned starts and inertia smoothing, with gap cleanliness and brush upkeep as the maintenance core.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 21972 for eddy-current motor standards and GB/T 12668 for adjustable speed systems. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Running below half speed continuously without derating: slip heat pushes the clutch past 150 C and magnets and insulation age fast
② Choosing an open-type clutch in dust without purging: the gap packs solid and the first start twists the output shaft off
③ Wiring the tacho feedback backwards: positive feedback slams the field to maximum and the output races to its mechanical limit

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.