A DC motor turns because current-carrying armature conductors sit in the field produced by the stator poles. This page walks through the stator, armature, commutator and brushes, and shows what to inspect first on the shop floor.
The stator field winding carries direct current and sets up a steady flux across the air gap. The armature winding sits in rotor slots and connects to the commutator bars. Force on a current-carrying conductor follows F = B·I·L, so torque is proportional to flux times armature current: T = Ct·Φ·Ia. The frame closes the magnetic circuit, and the end-shield bearings keep the air gap uniform.
The commutator with the brushes acts as a mechanical rectifier: every half turn it swaps the current direction in each coil so the torque keeps one direction. Brushes run at a pressure of roughly 15 to 25 kPa; below 15 mm of brush length or with a weak spring the contact starts sparking. A uniform brown patina on the commutator is healthy, while bright bare copper means the film has not formed.
On site, grade the sparking first: light point sparking at the brush edge is acceptable, heavy streaking with long sparks means stop the machine. Usual causes in order are mixed brush grades, unbalanced spring pressure, commutator runout above 0.05 mm, and mica not undercut. Replace brushes as a full set of one grade and bed each face to at least 80 percent contact before loading.
| Part | Healthy state | Fault sign | Usual cause |
|---|---|---|---|
| Brushes | Even wear, 15~25 kPa | Sparking, vibration | Unequal pressure, mixed grades |
| Commutator | Uniform brown patina | Black bands, scoring | Runout, mica not undercut |
| Armature winding | Insulation resistance OK | Shorted turns, heating | Carbon dust, overload |
| Field winding | Stable field current | Speed runs away | Turn fault, loose joint |
| Bearings | Low rise, no noise | Noise, hot housing | Dry grease, misalignment |
| Insulation | 1 MΩ per kV cold | Ground fault | Moisture, ageing |
Use this table during the first walk-around. Grade the sparks, then measure brush pressure and commutator runout, and only then test winding insulation and field current. Most DC motor faults show up before you even open the terminal box.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1311 for DC machine test methods and IEC 60204-1 for electrical safety of machinery. Always check the device datasheet and the product design file for ratings and derating.